1. Introduction to CTI (Comparative Tracking Index)

The Comparative Tracking Index (CTI) is an important electrical property of PCB (Printed Circuit Board) materials. It indicates how resistant the surface of an insulating material is to electrical tracking when exposed to electrical stress, moisture, and contamination.

Electrical tracking occurs when a conductive path gradually forms across the surface of an insulating material. Once this path develops, leakage current can increase and may eventually result in insulation failure, arcing, or short circuits.

CTI is expressed in volts (V). In general, a higher CTI value indicates better resistance to surface tracking.

For PCB engineers, CTI becomes particularly important in:

  • High-voltage PCB designs
  • Power supplies and power electronics
  • Automotive electronics
  • Industrial control equipment
  • Outdoor electronics
  • High-humidity environments
  • Applications requiring reduced creepage distances

CTI should therefore be considered together with operating voltage, pollution degree, creepage distance, material group, environmental conditions, and applicable safety standards.

This guide explains CTI ratings, IEC 60112 testing, PCB material selection, and the practical relationship between CTI and high-voltage PCB design.

CTI Comparison

CTI Comparison


2. What Is CTI Rating?

CTI stands for Comparative Tracking Index.

It is determined by testing the surface of an insulating material under controlled conditions and evaluating its resistance to electrical tracking.

A higher CTI does not mean that the PCB can simply operate at that voltage.

For example, a PCB laminate with a CTI of 600 V should not be interpreted as having a safe working voltage of 600 V.

Instead, CTI is a material property used in insulation coordination and creepage-distance evaluation.

This distinction is important because CTI is sometimes confused with:

  • Dielectric strength
  • Breakdown voltage
  • Working voltage
  • Hi-Pot test voltage

These parameters describe different electrical characteristics.

CTI vs. Breakdown Voltage

CTI primarily evaluates the resistance of an insulating surface to tracking under contamination.

Breakdown voltage or dielectric strength evaluates the ability of an insulating material to withstand an electric field through its bulk thickness before dielectric breakdown occurs.

Therefore:

CTI → surface insulation / tracking resistance

Dielectric strength → insulation through the material

Both can be important in high-voltage PCB design, but they should not be treated as the same specification.

For more information about dielectric breakdown, see our guide to FR4 breakdown voltage.


3. CTI Classification and Material Groups

PCB materials are commonly grouped according to CTI values for insulation coordination.

A practical reference is:

Material Group CTI Range
Group I CTI ≥ 600 V
Group II 400 V ≤ CTI < 600 V
Group IIIa 175 V ≤ CTI < 400 V
Group IIIb 100 V ≤ CTI < 175 V

Higher CTI materials generally provide greater resistance to surface tracking.

Why Does This Matter?

The CTI material group can influence the required creepage distance between conductive parts.

In many applications, a higher-CTI material can help engineers achieve the required insulation performance with a smaller creepage distance than a lower-CTI material, depending on the applicable standard, working voltage, pollution degree, and insulation category.

This can become particularly valuable when designing compact high-voltage electronics.

However, engineers should always calculate creepage and clearance according to the safety standard applicable to the final product.


4. How Is CTI Tested? – IEC 60112

CTI is commonly determined according to IEC 60112, which specifies a method for evaluating the tracking resistance of solid insulating materials.

During the test, two electrodes are positioned on the surface of the material.

A conductive test solution is then applied between the electrodes while a specified voltage is maintained.

The objective is to determine whether conductive tracking develops on the material surface under controlled contamination.

Simplified CTI Test Process

1. Sample Preparation

A representative insulating material specimen is prepared according to the applicable test requirements.

2. Electrode Placement

Two electrodes are placed on the material surface at the specified spacing.

3. Test Solution Application

Drops of conductive solution are applied between the electrodes at controlled intervals.

4. Electrical Stress

A specified voltage is applied across the electrodes.

5. Tracking Evaluation

The specimen is monitored for tracking failure according to the test criteria.

The resulting CTI value provides a standardized way to compare the surface tracking resistance of insulating materials.

Important Note

CTI testing is a material test.

It should not be confused with electrical testing of a finished PCB, such as:

  • Flying probe testing
  • Fixture electrical testing
  • Hi-Pot testing
  • Functional testing

These tests evaluate different aspects of PCB quality and electrical performance.


5. CTI Comparison of PCB Materials

There is no single CTI value that applies to every FR4, polyimide, ceramic, or metal-core material.

CTI depends on the exact laminate formulation and material grade.

This is particularly important when specifying PCB materials.

Standard FR4

Standard FR4 laminates can have significantly different CTI ratings depending on their resin formulation and manufacturer.

General-purpose FR4 is widely used because it provides a good balance between:

  • Electrical insulation
  • Mechanical strength
  • Thermal performance
  • Manufacturability
  • Cost

However, standard FR4 should not automatically be assumed to provide CTI ≥ 600 V.

The laminate datasheet should always be checked.

High-CTI FR4

High-CTI FR4 is specifically formulated to provide improved resistance to electrical tracking.

Materials with CTI ≥ 600 V are particularly useful in applications such as:

  • EV electronics
  • Power conversion
  • Charging systems
  • Industrial power supplies
  • High-voltage control boards
  • Outdoor electronics

High-CTI FR4 allows designers to maintain the familiar manufacturing characteristics of FR4 while improving surface insulation performance.

Polyimide

Polyimide materials are commonly selected when high-temperature capability, dimensional stability, or flexible construction is required.

However, polyimide should not automatically be considered a high-CTI material.

Its actual CTI rating depends on the specific material system.

Ceramic Substrates

Ceramic substrates such as alumina and aluminum nitride offer excellent electrical insulation and thermal properties.

However, ceramic materials should be evaluated according to their own electrical specifications rather than assuming a universal CTI value.

They are often selected for:

  • Power modules
  • High-temperature electronics
  • LED applications
  • High-power electronics
  • Thermal management

Metal-Core PCB Materials

For aluminum or copper-based MCPCBs, the insulation performance is primarily determined by the dielectric layer between the copper circuit and metal base.

Therefore, engineers should check the exact dielectric material specifications, including:

  • CTI
  • Dielectric strength
  • Thermal conductivity
  • Insulation thickness
  • Thermal resistance

Material type alone is not enough to determine tracking performance.


6. Why Is CTI Important in PCB Design?

CTI becomes increasingly important as PCB operating voltage increases and electronic products become smaller.

6.1 Reducing Surface Tracking Risk

Moisture, dust, ionic contamination, and other environmental factors can create leakage paths across the PCB surface.

Higher-CTI materials provide greater resistance to the formation of permanent conductive tracks.

6.2 Supporting High-Voltage PCB Design

Power electronics may contain hundreds of volts between adjacent conductors.

Material selection therefore becomes part of the insulation system rather than simply a mechanical choice.

6.3 Supporting Compact PCB Layouts

One of the most important practical benefits of higher-CTI materials is their relationship with creepage requirements.

Depending on the applicable safety standard and design conditions, a higher CTI material group may allow a reduced required creepage distance.

This can be valuable in:

  • Compact power supplies
  • EV electronics
  • Industrial controllers
  • Charging equipment
  • High-density power modules

6.4 Improving Reliability in Contaminated Environments

CTI is especially relevant when PCB assemblies operate in environments containing:

  • Moisture
  • Dust
  • Condensation
  • Industrial contamination
  • Conductive residues

These conditions increase the importance of surface insulation performance.


7. CTI, Creepage and Clearance: What Is the Difference?

These three terms are related but should not be confused.

CTI

CTI describes the tracking resistance of the insulating material surface.

Creepage Distance

Creepage is the shortest distance along the surface of an insulating material between two conductive parts.

Because creepage follows the material surface, CTI can influence the required creepage distance.

Clearance Distance

Clearance is the shortest distance through air between two conductive parts.

CTI generally does not directly determine clearance requirements.

Clearance is more strongly influenced by factors such as:

  • Working voltage
  • Transient overvoltage
  • Pollution degree
  • Altitude
  • Applicable safety standard

A good high-voltage PCB design must consider CTI, creepage, and clearance together.

CTI, Creepage and Clearance

CTI, Creepage and Clearance


8. How to Select the Right CTI Material for a PCB

Selecting a PCB material based only on the statement “high CTI” is not enough.

Engineers should evaluate several factors together:

Operating Voltage

Higher-voltage applications generally require greater attention to insulation coordination and tracking resistance.

Creepage Requirements

Determine the required creepage distance according to the applicable product standard.

If PCB space is limited, a higher CTI material may provide additional design flexibility.

Operating Environment

Consider whether the PCB will operate in:

  • High humidity
  • Outdoor conditions
  • Industrial contamination
  • Automotive environments
  • Condensation-prone locations

Temperature Requirements

CTI is only one material property.

The laminate must also meet the required:

  • Tg
  • Td
  • T288
  • Z-axis expansion
  • Thermal cycling performance

PCB Manufacturing Requirements

Material selection must also consider:

  • Layer count
  • Copper thickness
  • PCB thickness
  • Hole structure
  • Lamination conditions
  • Surface finish
  • Reliability requirements

A PCB material that performs well electrically must still be manufacturable within the required PCB structure.


9. High-CTI FR4 in Automotive and Power Electronics

The growth of electric vehicles, charging systems, renewable energy, and industrial power electronics has increased interest in high-CTI PCB materials.

Typical applications include:

  • Battery management systems (BMS)
  • On-board chargers
  • DC/DC converters
  • EV power control systems
  • Solar inverters
  • Industrial power supplies
  • Motor drives
  • Charging stations

These products often combine higher operating voltage, compact PCB layouts, elevated temperatures, and demanding reliability requirements.

For these applications, specifying a high-CTI laminate can be an important part of the overall insulation strategy.

However, CTI should never be evaluated independently.

A reliable design also requires proper consideration of:

creepage + clearance + material thickness + dielectric strength + contamination + operating voltage + manufacturing quality.


10. CTI Requirements from a PCB Manufacturing Perspective

From a PCB manufacturer’s perspective, one common problem is receiving a fabrication drawing that specifies only:

FR4

For conventional low-voltage electronics, this may sometimes be sufficient.

For high-voltage applications, however, engineers should consider specifying the required material characteristics more clearly.

For example:

FR4, CTI ≥ 600 V

is much clearer than simply:

FR4

The PCB manufacturer can then verify whether the selected laminate meets the required CTI specification before production.

The same principle applies to other important requirements such as:

  • Tg
  • Copper thickness
  • Finished PCB thickness
  • Surface finish
  • Impedance
  • UL requirements
  • Flammability rating

Good PCB documentation reduces material substitution risk and prevents misunderstandings between PCB designers and manufacturers.

For engineers who want to understand how these requirements move through production, our PCB manufacturing process guide explains the major fabrication stages from material preparation through final inspection.


11. Conclusion: Why CTI Rating Matters in PCB Manufacturing

CTI is an important material parameter for PCB designs where electrical tracking and surface insulation are reliability concerns.

The most important points are:

  • Higher CTI means greater resistance to surface electrical tracking.
  • CTI is not the same as breakdown voltage or working voltage.
  • CTI can influence creepage-distance requirements.
  • The exact CTI value depends on the specific laminate grade, not simply whether the material is FR4, polyimide, ceramic, or MCPCB.
  • High-voltage PCB design requires CTI, creepage, clearance, dielectric strength, environment, and manufacturing capability to be considered together.

For automotive, industrial, power electronics, and other high-voltage applications, material selection should therefore begin during the PCB design and DFM stage rather than after the PCB enters production.

SQPCB supports prototype and volume PCB board manufacturing, including high-CTI FR4 and other materials for industrial, automotive, power electronics, and high-reliability applications.

For additional PCB sourcing and manufacturing information, visit PCB Supplier.


Frequently Asked Questions About CTI Rating

What does CTI mean in PCB materials?

CTI stands for Comparative Tracking Index. It indicates the resistance of an insulating material to electrical tracking across its surface under standardized test conditions.

Is a higher CTI rating better?

Generally, yes. A higher CTI indicates better resistance to surface tracking. However, PCB material selection should also consider dielectric strength, thermal properties, mechanical reliability, cost, and applicable safety requirements.

Is CTI the same as PCB breakdown voltage?

No. CTI evaluates surface tracking resistance, while dielectric strength or breakdown voltage relates to electrical breakdown through an insulating material. They are different material characteristics.

What is CTI 600?

A CTI value of 600 V or greater places a material in Material Group I for insulation-coordination purposes. High-CTI FR4 materials are commonly considered for high-voltage and demanding electrical applications.

Does CTI affect PCB creepage distance?

Yes. CTI is one of the factors used when determining creepage requirements in insulation coordination. Higher-CTI materials may allow smaller required creepage distances under certain standards and operating conditions.

Does CTI affect clearance distance?

Not in the same way. Clearance is the shortest distance through air and is primarily determined by voltage, transient conditions, altitude, pollution degree, and applicable safety standards.

Is all FR4 CTI 600?

No. FR4 is a material family, not a single CTI specification. Different FR4 laminate grades can have different CTI values. Always check the manufacturer’s laminate datasheet when CTI is a design requirement.

What CTI should be specified for an automotive PCB?

There is no single CTI requirement for every automotive PCB. The appropriate CTI depends on operating voltage, insulation requirements, environment, product standards, and PCB layout. Some high-voltage automotive applications specify CTI ≥ 600 V, but this should be determined from the actual design requirements.